Driver setup for Yealink RoomBar AXX
You can monitor and control your Yealink RoomBar AXX series devices, via RoomConnect, connected to your network.
Let's start by configuring your device:
- Verify the IP address of your Yealink RoomBar (e.g., 192.168.0.1) and check the connection to the administration console accessible at https://192.168.0.1/
- Once authenticated, you will see the following screen: Please note the IP address used for device management (highlighted in red on the screen below). Then go to System > Device Manage > 3rd DM Service and enable HTTPS API and enter a password for the API in HTTPS Authentication Password. Finally, click Confirm.
Next, let's configure the driver in the Zebrix Control administration interface:
- URL : The URL of the Yealink RoomBar, like following pattern https://ip (for example : https://192.168.0.1).
- Username : The account used to log in to the device (default: admin).
- Password : The password used to log in to the device. Enter the password you configured when enabling the HTTPS API.
- Allow self-signed certificate : Check this box if the device's SSL certificate is self-signed.
Your videoconferencing device is now added as a device in Zebrix Control.
Contact Zebrix support for more information.